Cano J, Campo J. Bone implant sockets made using three different procedures: a stability study in dogs. J Clin Exp Dent. 2012;4(4):e217-20.

 

doi:10.4317/jced.50803

http://dx.doi.org/doi:10.4317/jced.50803

 

References

1. Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981; 52:155–70.
http://dx.doi.org/10.3109/17453678108991776 
PMid:7246093

2. Ivanoff CJ, Sennerby L, Lekholm U. Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits. Clin Oral Implants Res. 1996;7:120-7.
http://dx.doi.org/10.1034/j.1600-0501.1996.070205.x 
PMid:9002830

3. Huang HM, Lee SY, Yeh CY, Lin CT. Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach. Clin Oral Implants Res. 2001;13:65-74.
http://dx.doi.org/10.1034/j.1600-0501.2002.130108.x
PMid:12005147

4. Minkin C, Marinho VC. Role of the osteoclast at the bone implant interface. Adv Dent Res. 1999;13:49-56.
http://dx.doi.org/10.1177/08959374990130011401
PMid:11276746

5. Sennerby L, Ericson LE, Thomsen P, Lekholm U, Astrand P. Structure of bone –titanium interface in retrieved clinical oral implants. Clin Oral Implants Res. 1991;2:103-11.
http://dx.doi.org/10.1034/j.1600-0501.1991.020302.x
PMid:1843463

6. Quesada-García MP, Prados-Sánchez E, Olmedo-Gaya MV, Muñoz-Soto E, González-Rodríguez MP, Vallecillo-Capilla M. Measurement of dental implant stability by resonance frequency analysis: a review of the literature.Med Oral Patol Oral Cir Bucal. 2009;14:e538-46.
PMid:19680211

7. Di Alberti L, Donnini F, Di Alberti C, Camerino M. A comparative study of bone densitometry during osseointegration: piezoelectric surgery versus rotary protocols. Quintessence Int. 2010;41:639-44.
PMid:20657852

8. Krafft T, Graef F, Winter W, Wichmann M, Karl M. Use of osteotomes for implant bed preparation-effect on material properties of bone and primary implant stability. 
J OralImplantol. 2011 Jul 5.
http://dx.doi.org/10.1563/AAID-JOI-D-10-00187
PMid:21728839

9. 
Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant–tissue interface using resonance frequency analysis. Clin Oral Implants Res. 1996;7:261–7.
http://dx.doi.org/10.1034/j.1600-0501.1996.070308.x
PMid:9151590

10. Meredith N. A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants. Crit Rev Biomed Eng. 1998;26:275-91.
PMid:10065892

11. Scipioni A, Bruschi GB, Giargia M, Berglundh T, Lindhe J. Healing at implants with and without primary bone contact. An experimental study in dogs. Clin Oral Implants Res. 1997;8:39-47.
http://dx.doi.org/10.1111/j.1600-0501.1997.tb00006.x
PMid:9586455

12. Sethi A, Kaus T. Maxillary ridge expansion with simultaneous implant placement: 5-year results of an ongoing clinical study. 
Int J Oral Maxillofac Implants. 2000;15:491-9.
PMid:10960981