Santamaría-Arrieta G, Brizuela-Velasco A, Fernández-González FJ, Chávarri-Prado D, Chento-Valiente Y, Solaberrieta E, Diéguez-Pereira M, Vega JA, Yurrebaso-Asúa J. Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis. J Clin Exp Dent. 2016;8(3):e307-11.

 

doi:10.4317/jced.52873

http://dx.doi.org/doi:10.4317/jced.52873

 

References

1. Brĺnemark PI, Hansson BO, Adell R, Breine U, Lindström J, Hallén O, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1-132.
PMid:356184

 

2. Shalabi MM, Wolke JGC, Jansen J. The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model. Clin Oral Implants Res. 2006;17:172-8.
http://dx.doi.org/10.1111/j.1600-0501.2005.01202.x
PMid:16584413

 

3. Shalabi MM, Wolke JGC, de Ruijter AJE, Jansen J. Histological evaluation of oral implants inserted with different surgical techniques into the trabecular bone of goats. Clin Oral Implants Res. 2007;18:489-95.
http://dx.doi.org/10.1111/j.1600-0501.2007.01362.x
PMid:17517059

 

4. Ahn SJ, Leesungbok R, Lee SW, Heo YK, Kang KL. Differences in implant stability associated with various methods of preparation of the implant bed: An in vitro study. J Prosthet Dent. 2012;107:366-72.
http://dx.doi.org/10.1016/S0022-3913(12)60092-4

PMid:22633592

 

5. Moon SH, Um HS, Lee JK, Chang BS, Lee MK. The effect of implant shape and bone preparation on primary stability. J Periodontal Implant Sci. 2010;40:239-43.
http://dx.doi.org/10.5051/jpis.2010.40.5.239
PMid:21072221 PMCid:PMC2967812

 

6. Kang IH, Lim YJ, Kim MJ, Kim CW. A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis. J Adv Prosthodont. 2011;3:190.
http://dx.doi.org/10.4047/jap.2011.3.4.190
PMid:22259702 PMCid:PMC3259444

 

7. Albrektsson T, Brĺnemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52:155-70.
http://dx.doi.org/10.3109/17453678108991776
PMid:7246093

 

8. Glauser R, Sennerby L, Meredith N, Rée A, Lundgren A, Gottlow J, et al. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res. 2004;15:428-34.
http://dx.doi.org/10.1111/j.1600-0501.2004.01036.x
PMid:15248877

 

9. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res. 1996;7:261-7.
http://dx.doi.org/10.1034/j.1600-0501.1996.070308.x
PMid:9151590

 

10. Degidi M, Perrotti V, Strocchi R, Piattelli A, Iezzi G. Is insertion torque correlated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants. Clin Oral Implants Res. 2009;20:778-81.
http://dx.doi.org/10.1111/j.1600-0501.2008.01599.x
PMid:19486080

 

11. Kahraman S, Bal BT, Asar N V, Turkyilmaz I, Tözüm TF. Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants. J Oral Rehabil. 2009;36:755-61.
http://dx.doi.org/10.1111/j.1365-2842.2009.01990.x
PMid:19758410

 

12. Degidi M, Daprile G, Piattelli A. Primary stability determination of implants inserted in sinus augmented sites: 1-step versus 2-step procedure. Implant Dent. 2013;22:530-3.
http://dx.doi.org/10.1097/ID.0b013e31829f1ef2
PMid:24013393

 

13. Nkenke E, Hahn M, Weinzierl K, Radespiel-Tröger M, Neukam FW, Engelke K. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res. 2003;14:601-9.
http://dx.doi.org/10.1034/j.1600-0501.2003.00937.x
PMid:12969364

 

14. Da Cunha HA, Francischone CE, Filho HN, de Oliveira RCG. A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading. Int J Oral Maxillofac Implants. 2004;19:578-85.

PMid:15346756

 

15. Akca K, Akkocaoglu M, Comert A, Tekdemir I, Cehreli MC. Bone strains around immediately loaded implants supporting mandibular overdentures in human cadavers. Int J Oral Maxillofac Implants. 2007;22:101-9.
PMid:17340903

 

16. Bayarchimeg D, Namgoong H, Kim BK, Kim MD, Kim S, Kim T, et al. Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test. J Periodontal Implant Sci. 2013;43:30-6.
http://dx.doi.org/10.5051/jpis.2013.43.1.30
PMid:23508040 PMCid:PMC3596632

 

17. García-Vives N, Andrés-García R, Rios-Santos V, Fernández-Palacín A, Bullón-Fernández P, Herrero-Climent M, et al. In vitro evaluation of the type of implant bed preparation with osteotomes in bone type IV and its influence on the stability of two implant systems. Med Oral Patol Oral Cir Bucal. 2009;14:455-60.

PMid:19718009

 

18. Baker J, Vora S, Bairam L, Kim H, Davis EL, Andreana S. Piezoelectric vs. conventional implant site preparation: ex vivo implant primary stability. Clin Oral Implants Res. 2012;23:433-7.
http://dx.doi.org/10.1111/j.1600-0501.2011.02286.x
PMid:22092442

 

19. Tricio J, van Steenberghe D, Rosenberg D, Duchateau L. Implant stability related to insertion torque force and bone density: An in vitro study. J Prosthet Dent. 1995;74:608-12.
http://dx.doi.org/10.1016/S0022-3913(05)80313-0

PMid:8778385

 

20. Pagliani L, Sennerby L, Petersson a, Verrocchi D, Volpe S, Andersson P. The relationship between resonance frequency analysis (RFA) and lateral displacement of dental implants: an in vitro study. J Oral Rehabil. 2013;27:221-7.
http://dx.doi.org/10.1111/joor.12024
PMid:23278128

 

21. Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res. 1998;43:192-203.
http://dx.doi.org/10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K

PMid:9619438

 

22. Mavrogenis a F, Dimitriou R, Parvizi J, Babis GC. Biology of implant osseointegration. J Musculoskelet Neuronal Interact. 2009;9:61-71.
PMid:19516081

 

23. Pilliar RM, Lee JM, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res. 1986;208:108-13.
http://dx.doi.org/10.1097/00003086-198607000-00023

PMid:3720113

 

24. Sřballe K, Hansen ES, B-Rasmussen H, Jřrgensen PH, Bünger C. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res. 1992;10:285-99.
http://dx.doi.org/10.1002/jor.1100100216
PMid:1311039

 

25. Brunski JB. Avoid pitfalls of overloading and micromotion of intraosseous implants. Dent Implantol Update. 1993;4:77-81.
PMid:7919404

 

26. Akkocaoglu M, Uysal S, Tekdemir I, Akca K, Cehreli MC. Implant design and intraosseous stability of immediately placed implants: a human cadaver study. Clin Oral Implants Res. 2005;16:202-9.
http://dx.doi.org/10.1111/j.1600-0501.2004.01099.x
PMid:15777330

 

27. Bardyn T, Gédet P, Hallermann W, Büchler P. Quantifying the influence of bone density and thickness on resonance frequency analysis: an in vitro study of biomechanical test materials. Int J Oral Maxillofac Implants. 2014;24:1006-14.

PMid:20162104

 

28. Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg. 1999;28:297-303.
http://dx.doi.org/10.1016/S0901-5027(99)80163-5

PMid:10416900

 

29. Bilhan H, Geckili O, Mumcu E, Bozdag E, Sünbüloğlu E, Kutay O. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone. J Oral Rehabil. 2010;37:900-7.
http://dx.doi.org/10.1111/j.1365-2842.2010.02117.x
PMid:20529176

 

30. Sennerby L, Andersson P, Pagliani L, Giani C, Moretti G, Molinari M, et al. Evaluation of a Novel Cone Beam Computed Tomography Scanner for Bone Density Examinations in Preoperative 3D Reconstructions and Correlation with Primary Implant Stability. Clin Implant Dent Relat Res. 2015;17:844-53.
http://dx.doi.org/10.1111/cid.12193
PMid:24373386