Paes-Junior TJA, Tribst JPM, Dal Piva AMO, Amaral M, Borges ALS, Gonçalves FCP. Stress distribution of complete-arch implant-supported prostheses reinforced with silica-nylon mesh. J Clin Exp Dent. 2019;11(12):e1163-9.

 

doi:10.4317/jced.56470

https://doi.org/10.4317/jced.56470

_________________________________________________________________________________________________________________

 

References

1. Ciftçi Y, Canay S. Stress distribution on the metal framework of the implant-supported fixed prosthesis using different veneering materials. Int J Prosthodont. 2001;14:406-411.

PMid: 12066633

 

2. Tribst JPM, Dal Piva AMO, Borges ALS, Bottino MA. Effect of implant number and height on the biomechanics of full arch prosthesis. Braz J Oral Sci. 2018;17:e18222.
https://doi.org/10.20396/bjos.v17i0.8653837

 

3. Gonçalves FCP, Amaral M, Borges ALS, Gonçalves LFM, Paes-Junior TJA. Fracture load of complete-arch implant-supported prostheses reinforced with nylon-silica mesh: An in vitro study. J Prosthet Dent. 2018;119:606-610.
https://doi.org/10.1016/j.prosdent.2017.05.018
PMid:28709676

 

4. Souza MP, Tribst JPM, de Oliveira Dal Piva AM, Borges ALS, de Oliveira S, da Cruz PC. Capacity to maintain placement torque at removal, single load-to-failure, and stress concentration of straight and angled abutments. Int J Periodontics Restorative Dent. 2019;39:213-218.
https://doi.org/10.11607/prd.3998
PMid:30794257

 

5. Drago C. Ratios of cantilever lengths and anterior-posterior spreads of definitive hybrid full-arch, screw-retained prostheses: results of a clinical study. J Prosthodont. 2018;27:402-408.
https://doi.org/10.1111/jopr.12519
PMid:27416302

 

6. Koyano K, Esaki D. Occlusion on oral implants: current clinical guidelines. J Oral Rehabil. 2015;42:153-161.
https://doi.org/10.1111/joor.12239
PMid:25284468

 

7. Joshi N, Piermatti J, Nahon M, Balshi T. Management of biotechnical complications associated with a full-arch implant restoration using digital and conventional workflows: a clinical report. J Prosthodont. 2019;28:483-487.
https://doi.org/10.1111/jopr.13066
PMid:30997930

 

8. Paes-Junior TJDA, de Castro HL, Borges ALS, Della Bona A, Gonçalves FDCP. A novel silica-nylon mesh reinforcement for dental prostheses. Adv Mater Sci Eng. 2017;2017:1-6.
https://doi.org/10.1155/2017/3709171

 

9. Almeida CS, Amaral M, de Cássia Papaiz Gonçalves F, de Arruda Paes- Junior TJ. Effect of an experimental silica-nylon reinforcement on the fracture load and flexural strength of bisacrylic interim partial fixed dental prostheses. J Prosthet Dent. 2016;115:301-305.
https://doi.org/10.1016/j.prosdent.2015.08.009
PMid:26548883

 

10. Rodrigues VA, Tribst JP, Santis LR, Borges AL, Nishioka RS. Biomechanical effect of inclined implants in fixed prosthesis: strain and stress analysis. Rev Odontol UNESP. 2018;47:237-243.
https://doi.org/10.1590/1807-2577.05418

 

11. Mericske-Stern R, Assal P, Mericske E, Bürgin W. Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants. In J Oral Maxillofac Implants. 1995;10:345-353.
https://doi.org/10.1097/00008505-199600510-00032

PMid: 7615331

 

12. Tribst JPM, Dal Piva AMO, Madruga CFL, Valera MC, Borges ALS, Bresciani E, et al. Endocrown restorations: Influence of dental remnant and restorative material on stress distribution. Dent Mater. 2018;34:1466-1473.
https://doi.org/10.1016/j.dental.2018.06.012
PMid:29935769

 

13. Fujimoto T, Niimi A, Murakami I, Ueda M. Use of new magnetic attachments for implant-supported overdentures. J Oral Implantol. 1998;24:147-151.
https://doi.org/10.1563/1548-1336(1998)024<0147:UONMAF>2.3.CO;2

PMid: 9893521

 

14. Pjetursson BE, Bragger U, Lang NP, Zwahlen M. Comparison of survivaland complication rates of tooth-supported fixed dental prosthesis (FDPs)and implant-supported FDPs and single crowns (SCs Review). Clin Oral Implants Res. 2008;19:326-328.

PMid: 17594374

 

15. Bornstein MM, Halbritter S, Harnisch H, Weber HP, Buser D. A retrospective analysis of patients referred for implant placement to a specialty clinic: indications, surgical rocedures, and early failures. Int J Oral Maxillofac Implants. 2008;23:1109-1116.

PMid: 19216281

 

16. Rangert B, Jemt T, Jorneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Impl. 1989;4:241-247.

PMid: 2700747

 

17. Sahin S, Cehreli MC, Yalçin E. The influence of functional forces on the biomechanics of implant-supported prostheses-a review. J Dent. 2002;30:271-282.
https://doi.org/10.1016/S0300-5712(02)00065-9

PMid: 12554107

 

18. Kim Y, Oh TJ, Misch CE, Wang HL. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale. Clin Oral Impl Res. 2005;16:26-35.
https://doi.org/10.1111/j.1600-0501.2004.01067.x
PMid:15642028

 

19. Frost HM. Wolff's Law and bone's structural adaptations to mechanical usage: an overview for clinicians. Angle Orthod. 1994;64:175-188.

PMid: 8060014

 

20. Rubo JH, Capello Souza EA. Finite-element analysis of stress on dental implant prosthesis. Clin Implant Dent Relat Res. 2010;12:105-113.
https://doi.org/10.1111/j.1708-8208.2008.00142.x
PMid:19220846

 

21. Yalikun K, Kanazawa M, Tanoue M, Minakuchi S. In vitro variation measurement of mandibular denture displacement resistance involving 1 to 3 implants. J Prosthet Dent. 2019;121:492-497.
https://doi.org/10.1016/j.prosdent.2018.03.036
PMid:30391057

 

22. Shen H, Di P, Luo J, Lin Y. Clinical assessment of implant-supported full-arch immediate prostheses over 6 months of function. Clin Implant Dent Relat Res. 2019;21:473-481.
https://doi.org/10.1111/cid.12784
PMid:31067003

 

23. Wagner F, Seemann R, Marincola M, Ewers R. Fiber-reinforced resin fixed prostheses on 4 short implants in severely atrophic maxillas: 1-year results of a prospective cohort study. J Oral Maxillofac Surg. 2018;76:1194-1199.
https://doi.org/10.1016/j.joms.2018.02.001
PMid:29534871