Silva RV,
Alcalde MP, Horta MCR, Rodrigues CT, da Silveira FF, Hungaro MA, Nunes E. Root
canal shaping of curved canals by reciproc blue system and protaper gold: A
micro computed tomographic study. J Clin Exp Dent. 2021;13(2):e112-8.
doi:10.4317/jced.57180
https://doi.org/10.4317/jced.57180
___________
References
1.
Siqueira Jr. JF, Rôças IN. Clinical implications and microbiology of
bacterial persistence after treatment procedures. J Endod. 2008:34:1291-301. |
|
|
|
2.
Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending
and torsional properties of nitinol root canal files. J Endod. 1988:14:
346-51. PMid:3251996 |
|
|
|
3.
Gambarini G. Rationale for the use of low-torque endodontic motors in root
canal instrumentation. Dent Traumatol. 2000:16:95-100. |
|
|
|
4.
Bergmans L, Van Cleynenbreugel J, Wevers M, Lambrechts P. Mechanical root
canal preparation with NiTi rotary instruments: rationale, performance and
safety-status report for the American Journal of Dentistry. Am J Dent.
2001:14:324-33. PMid:11803999 |
|
|
|
5.
Peters OA. Current challenges and concepts in the preparation of root canal
systems: a review. J Endod. 2004:30:559-67. PMid:15273636 |
|
|
|
6.
Shen Y, Zhou HM, Zheng YF, Peng B, Haapasalo M. Current challenges and
concepts of the thermomechanical treatment of nickel-titanium instruments. J
Endod. 2013:39:163-72. PMid:23321225 |
|
|
|
7.
Hieawy A, Haapasalo M, Zhou H, Wang ZJ, Shen Y. Phase transformation behavior
and resistance to bending and cyclic fatigue of Protaper Gold and Protaper
Universal instruments. J Endod. 2015:41:1134-8. |
|
|
|
8.
Plotino G, Grande NM, Cotti E, Testarelli L, Gambarini G. Blue treatment
enhances cyclic fatigue resistance of vortex nickel-titanium rotatory files.
J Endod. 2014b:40:1451-3. |
|
|
|
9.
De-Deus G, Silva EJN, Vieira VTL, Belladonna FG, Elias CN, Plotino G, et al.
Blue thermomechanical treatment optimizes fatigue resistance and flexibility
of the reciproc files. J Endod. 2017:43:462-6. |
|
|
|
10.
Versiani MA, Leoni GB, Steier L, De-Deus G, Tassani S, Pécora JD, et al.
Micro-computed tomography study of ovalshaped canals prepared with
Self-Adjusting file, Reciproc, WaveOne, and ProTaper universal systems. J
Endod. 2013:39:1060-6. |
|
|
|
11.
Schneider SW. A comparison of canal preparations in straight and curved root
canals. Oral Surg Oral Med Oral Pathol. 1971:32:271-5. PMid:5284110 |
|
|
|
12.
Schafer E, Diez C, Hoppe W, Tepel J. Roentgenographic in investigation of
frequency and degree of canal curvatures in human permanent teeth. J Endod. 2002:28:211-6. |
|
|
|
13.
Gambill JM, Alder M, Del Rio E. Comparison of nickel-titanium and stainless
stell hand-file instrumentation using computed tomography. J Endod. 1996:22:369-75. PMid:8935064 |
|
|
|
14.
Kirchhoff AL, Chu R, Mello I, Garzon AD, dos Santos M, Cunha RS. Glide path
management with single and multiple instrument rotatory systems in curved
canals: A micro-computed tomographic study. J Endod. 2015:41:1880-3. |
|
|
|
15.
Paqué F, Laib A, Gautschi H, Zehnder M. Hard-tissue debris accumulation
analysis by highresolution computed tomography scans. J Endod. 2009:35:1044-7. |
|
|
|
16.
Thompson SA, Dummer PM. Shaping ability of Hero 642 rotary nickel-titanium
instruments in simulated root canals: part 2. Int Endod J. 2000:33:255-61. |
|
|
|
17.
Gagliardi J, Versiani MA, de Sousa-Neto MD, Plazas- Garzon A, Basrani B.
Evaluation of the shaping characteristics of ProTaper Gold, ProTaper NEXT,
and ProTaper Universal in curved canals. J Endod. 2015:41:1718-24. |
|
|
|
18.
Sant'Anna Júnior A, Cavenago BC, Ordinola-Zapata R, De-Deus G, Bramante CM,
Duarte MA. The effect of larger apical preparations in the danger zone of
lower molars prepared using the Mtwo and Reciproc systems. J Endod. 2014:40:1855-9. |
|
|
|
19.
Wu MK, R'oris A, Barkis D, Wesselink PR. Prevalence and extent of long oval
canals in the apical third. Oral Surg Oral Med Oral Pathol Oral Radiol Endod.
2000:89:739-43. |
|
|
|
20.
Plotino G, Giansiracusa Rubini A, Grande NM, Testarelli L, Gambarini G. Cutting
efficiency of Reciproc and WaveOne reciprocating instruments. J Endod.
2014a:40:1228-30. |
|
|
|
21.
Elayouti, A, Chu AL, Kimionis I, Klein C, Weiger R, Löst C. Efficacy of
rotary instruments with greater taper in preparing oval root canals. Int
Endod J. 2008:41:1088-92. |
|
|
|
22.
Ferreira F, Adeodato C, Barbosa I, Adoud L, Scelza P, Zaccaro Scelza M.
Movement kinematics and cyclic fatigue of NiTi rotary instruments: a
systematic review. Int Endod J. 2017:50:143-52. |
|
|
|
23.
Marceliano-Alves MFV, Sousa-Neto MD, Fidel SR, Steier L, Robinson JP, Pécora
JD, et al. Shaping ability of single-file reciprocating and heat-treated
multifile rotary systems: a micro-CT study. Int Endod J. 2015:48:1129-36. |
|
|
|
24.
Gao Y, Gutmann JL, Wilkinson K, Maxwell R, Ammon D. Evaluation of the impacto
of raw materials on the fatigue and mechanical properties of ProFile Vortex
rotatory instruments. J Endod. 2012:38:398-401. |
|
|
|
25.
Nagendrababu V, Ahmed, HMA. Shaping properties and outcomes of nickel
titanium rotary and reciprocation systems using Micro-Computed Tomography: A
systematic review. Quintessence Int. 2019:50:186-195. PMid:30773570 |
|
|
|
26.
Sousa-Neto MD, Silva-Sousa YC, Mazzi-Chaves JF, Carvalho KKT, Barbosa AFS,
Versiani MA, et al. Root canal preparation using micro-computed tomography
analysis: A literature review. Braz Oral Res. 2018:32:e66:20-43. PMid:30365607 |
|
|
|
27.
Sousa-Neto MD, Crozeta BM, Lopes FC, Mazzi-Chaves JF, Pereira RD, Silva-Sousa
AC, et al. A micro-CT evaluation of the performance of rotary and
reciprocating single- file systems in shaping ability of curved root canals.
Braz Oral Res. 2020:34:e039:1-9. |
|
|