Bittencourt ABBC, Rezende EOP, Campaner M, Bitencourt SB, dos Santos DM,
Pesqueira AA, Goiato MC. Stress distribution of multiple implant-supported
prostheses: Photoelastic and strain gauge analyses of external hexagon and
morse taper connections. J Clin Exp Dent. 2022;14(3):e235-40.
doi:10.4317/jced.59288
https://doi.org/10.4317/jced.59288
___________
References
1.
Lemos CAA, de Souza Batista VE, Almeida DA de F, Santiago Júnior JF, Verri
FR, Pellizzer EP. Evaluation of cement-retained versus screw-retained
implant-supported restorations for marginal bone loss: A systematic review
and meta-analysis. J Prosthet Dent. 2016;115:419-27. |
|
|
|
2.
Pennington J, Parker S. Improving quality of life using removable and fixed
implant prostheses. Compend Contin Educ Dent. 2012;33:268-270,272,274-276. PMid:22536660 |
|
|
|
3.
Pietrabissa R, Gionso L, Quaglini V, Di Martino E, Simion M. An in vitro
study on compensation of mismatch of screw versus cement-retained implant
supported fixed prostheses. Clin Oral Implants Res. 2000;11:448-57. |
|
|
|
4.
Tonella BP, Pellizzer EP, Ferraço R, Falcón-Antenucci RM, Carvalho PSP de,
Goiato MC. Photoelastic analysis of cemented or screwed implant-supported
prostheses with different prosthetic connections. J Oral Implantol. 2011;37:401-10. |
|
|
|
5.
Freitas ACJ, Bonfante EA, Rocha EP, Silva NRFA, Marotta L, Coelho PG. Effect
of implant connection and restoration design (screwed vs. cemented) in
reliability and failure modes of anterior crowns. Eur J Oral Sci. 2011;119:323-30. |
|
|
|
6.
Zarone F, Sorrentino R, Traini T, Di lorio D, Caputi S. Fracture resistance
of implant-supported screw- versus cement-retained porcelain fused to metal
single crowns: SEM fractographic analysis. Dent Mater. 2007;23:296-301. |
|
|
|
7.
Maeda Y, Satoh T, Sogo M. In vitro differences of stress concentrations for
internal and external hex implant-abutment connections: a short communication.
J Oral Rehabil. 2006;33:75-8. |
|
|
|
8.
Pita MS, Anchieta RB, Barão VAR, Garcia IRJ, Pedrazzi V, Assunção WG.
Prosthetic platforms in implant dentistry. J Craniofac Surg. 2011;22:2327-31. |
|
|
|
9.
Goiato MC, Shibayama R, Gennari Filho H, de Medeiros RA, Pesqueira AA, dos
Santos DM, et al. Stress distribution in implant-supported prostheses using
different connection systems and cantilever lengths: digital photoelasticity.
J Med Eng Technol. 2016;40:35-42. |
|
|
|
10.
da Rocha PVB, Freitas MA, de Morais Alves da Cunha T. Influence of screw
access on the retention of cement-retained implant prostheses. J Prosthet
Dent. 2013;109:264-8. |
|
|
|
11.
Shadid R, Sadaqa N. A comparison between screw- and cement-retained implant
prostheses. A literature review. J Oral Implantol. 2012;38:298-307. |
|
|
|
12.
Cehreli MC, Iplikçioğlu H, Bilir OG. The influence of the location of load
transfer on strains around implants supporting four unit cement-retained
fixed prostheses: in vitro evaluation of axial versus off-set loading. J Oral
Rehabil. 2002;29:394-400. |
|
|
|
13.
Bornstein MM, Halbritter S, Harnisch H, Weber H-P, Buser D. A retrospective
analysis of patients referred for implant placement to a specialty clinic:
indications, surgical procedures, and early failures. Int J Oral Maxillofac
Implants. 2008;23:1109-16. PMid:19216281 |
|
|
|
14.
do Prado Ribeiro P, Goiato MC, Pellizzer EP, Pesqueira AA, Haddad MF,
Alves-Rezende MCR, et al. Photoelastic stress analysis of different
attachment systems on implant-retained and conventional palatal obturator
prostheses. J Craniofac Surg. 2011;22:523-6. |
|
|
|
15.
do Prado Ribeiro P, Goiato MC, Pellizzer EP, Pesqueira AA, Haddad MF, de
Carvalho Dekon SF, et al. Photoelastic analysis of implant-retained and
conventional obturator prostheses with different attachment systems and soft
relining. J Craniofac Surg. 2011;22:797-800. |
|
|
|
16.
Gross MD, Nissan J. Stress distribution around maxillary implants in anatomic
photoelastic models of varying geometry. Part II. J Prosthet Dent. 2001;85:450-4. |
|
|
|
17.
Pesqueira AA, Goiato MC, dos Santos DM, Nobrega AS, Haddad MF, Andreotti AM,
et al. Stress analysis in oral obturator prostheses over parallel and tilted
implants: photoelastic imaging. J Biomed Opt. 2013;18:106009. |
|
|
|
18.
Goiato MC, Tonella BP, Ribeiro P do P, Ferraço R, Pellizzer EP. Methods used
for assessing stresses in buccomaxillary prostheses: photoelasticity, finite
element technique, and extensometry. J Craniofac Surg. 2009;20:561-4. |
|
|
|
19.
Cehreli M, Duyck J, De Cooman M, Puers R, Naert I. Implant design and
interface force transfer. A photoelastic and strain-gauge analysis. Clin Oral
Implants Res. 2004;15:249-57. |
|
|
|
20.
Akça K, Cehreli MC. A photoelastic and strain-gauge analysis of interface
force transmission of internal-cone implants. Int J Periodontics Restorative
Dent. 2008;28:391-9. PMid:18717378 |
|
|
|
21.
Cehreli MC, Akça K. Narrow-diameter implants as terminal support for occlusal
three-unit FPDs: a biomechanical analysis. Int J Periodontics Restorative
Dent. 2004;24:513-9. PMid:15626314 |
|
|
|
22.
Campaner M, Borges ACM, Camargo DA, Mazza LC, Bitencourt SB, De Medeiros RA,
et al. Influence of number of implants and connection systems on stress
behaviour of mandibular implant-retained overdentures: Photoelastic and
strain gauge analysis. J Clin Diagnostic Res. 2019;13:ZC04-9. |
|
|
|
23.
Campaner M, Borges ACM, Camargo DDA, Mazza LC, Bitencourt S basso, Medeiros
RA De, et al. Influence of Number of Implants and Connection Systems on
Stress Behaviour of Mandibular Implant-retained Overdentures: Photoelastic
and Strain Gauge Analysis. Journal of Clinical and Diagnostic Research.
2019;5:ZC04-ZC09. |
|
|
|
24.
Goiato MC, Sarauza Arsufi G, de Medeiros RA, Pesqueira AA, da Silva EVF,
Sonego MV, et al. Stress distribution of different implant connections
associated with multiple implant-supported prostheses. J Med Eng Technol.
2018;42:359-67. |
|
|
|
25.
Coelho Goiato M, Pesqueira AA, Falcón-Antenucci RM, Dos Santos DM, Haddad MF,
Bannwart LC, et al. Stress distribution in implant-supported prosthesis with
external and internal implant-abutment connections. Acta Odontol Scand.
2013;71:283-8. |
|
|
|
26.
Canay S, Hersek N, Akpinar I, Aşik Z. Comparison of stress distribution
around vertical and angled implants with finite-element analysis.
Quintessence Int. 1996;27:591-8. PMid:9180415 |
|
|
|
27.
Borges MS, Mucha JN. Avaliação da densidade óssea para instalação de
mini-implantes. Dental Press J Orthod. 2010;15:e1-9. |
|
|
|
28.
Guichet DL, Caputo AA, Choi H, Sorensen JA. Passivity of fit and marginal
opening in screw- or cement-retained implant fixed partial denture designs.
Int J Oral Maxillofac Implants. 2000;15:239-46. PMid:10795456 |