Palma-Carrió C, Maestre-Ferrín L, Peñarrocha-Oltra D, Peñarrocha-Dia-go MA, Peñarrocha-Diago M. Risk factors associated with early failure of dental implants. A literature review. Med Oral Patol Oral Cir Bucal. 2011 Jul 1;16 (4):e514-7.  

 

doi:10.4317/medoral.16.e514

http://dx.doi.org/doi:10.4317/medoral.16.e514

 

 

1. Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. (I). Success criteria and epidemiology. Eur J Oral Sci. 1998;106:527-51.
doi:10.1046/j.0909-8836..t01-2-.x
PMid:9527353

2. Manor Y, Oubaid S, Mardinger O, Chaushu G, Nissan J. Characteristics of early versus late implant failure: a retrospective study. J Oral Maxillofac Surg. 2009;67:2649-52.
doi:10.1016/j.joms.2009.07.050
PMid:19925986

3. Esposito M, Thomsen P, Ericson LE, Lekholm U. Histopathologic observations on early oral implant failures. Int J Oral Maxillofac Implants. 1999;14:798-810.
PMid:10612916

4. Kronström M, Svensson B, Erickson E, Houston L, Braham P, Persson GR. Humoral immunity host factors in subjects with failing or successful titanium dental implants. J Clin Periodontol. 2000;27:875-82.
doi:10.1034/j.1600-051x.2000.027012875.x
PMid:11140553

5. Kronström M, Svenson B, Hellman M, Persson GR. Early implant failures in patients treated with Brånemark System titanium dental implants: a retrospective study. Int J Oral Maxillofac Implants. 2001;16:201-7.
PMid:11324208

6. Van Steenberghe D, Jacobs R, Desnyder M, Maffei G, Quirynen M. The relative impact of local and endogenous patient-related factors on implant failure up to the abutment stage. Clin Oral Implants Res. 2002;13:617-22.
doi:10.1034/j.1600-0501.2002.130607.x
PMid:12519336

7. Noguerol B, Muñoz R, Mesa F, de Dios Luna J, O’Valle F. Early implant failure. Prognostic capacity of Periotest: retrospective study of a large sample. Clin Oral Implants Res. 2006;17:459-64.
doi:10.1111/j.1600-0501.2006.01250.x
PMid:16907779

8. Alsaadi G, Quirynen M, Komárek A, Van Steenberghe D. Impact of local and systemic factors on the incidence of oral implant failures, up to abutment connection. J Clin Periodontol. 2007;34:610-7.
doi:10.1111/j.1600-051X.2007.01077.x
PMid:17433044

9. Alsaadi G, Quirynen M, Michiles K, Teughels W, Komárek A, van Steenberghe D. Impact of local and systemic factors on the incidence of failures up to abutment connection with modified surface oral implants. J Clin Periodontol. 2008;35:51-7.
PMid:18034851

10. Bornstein MM, Halbritter S, Harnisch H, Weber HP, Buser D. A retrospective analysis of patients referred for implant placement to a specialty clinic: indications, surgical procedures, and early failures. Int J Oral Maxillofac Implants. 2008;23:1109-16.
PMid:19216281

11. Sverzut AT, Stabile GA, de Moraes M, Mazzonetto R, Moreira RW. The influence of tobacco on early dental implant failure. J Oral Maxillofac Surg. 2008;66:1004-9.
doi:10.1016/j.joms.2008.01.032
PMid:18423293

12. Testori T, Wiseman L, Woolfe S, Porter SS. A prospective multicenter clinical study of the Osseotite implant: four-year interim report. Int J Oral Maxillofac Implants. 2001;16:193-200.
PMid:11324207

13. Davarpanah M, Martinez H, Etienne D, Zabalegui I, Mattout P, Chiche F, et al. A prospective multicenter evaluation of 1,583 3i implants: 1- to 5-year data. Int J Oral Maxillofac Implants. 2002;17:820-8.
PMid:12507242

14. Roos-Jansåker AM, Lindahl C, Renvert H, Renvert S. Nine- to fourteen-year follow-up of implant treatment. Part I: implant loss and associations to various factors. J Clin Periodontol. 2006;33:283-9.
doi:10.1111/j.1600-051X.2006.00907.x
PMid:16553637

15. Koldsland OC, Scheie AA, Aass AM. Prevalence of implant loss and the influence of associated factors. J Periodontol. 2009;80:1069-75.
doi:10.1902/jop.2009.080594
PMid:19563286

16. Huynh-Ba G, Friedberg JR, Vogiatzi D, Ioannidou E. Implant failure predictors in the posterior maxilla: a retrospective study of 273 consecutive implants. J Periodontol. 2008;79:2256-61.
doi:10.1902/jop.2008.070602
PMid:19053914

17. Martínez-González JM, Barona-Dorado C, Cano-Sánchez J, Flórez-Rodríguez M, Cantero-Alvarez M. Clinical and radiographic behaviour of 290 dental implants with a surface treated with hydrofluoric acid and passivated with hydrofluoric and nitric acid: early loading results after 2 years. Med Oral Patol Oral Cir Bucal. 2005;10:355-61.
PMid:16056190

18. Leite MF, Santos MC, De Souza AP, Line SR. Osseointegrated implant failure associated with MMP-1 promotor polymorphisms (-1607 and -519). Int J Oral Maxillofac Implants. 2008;23:653-8.
PMid:18807561

19. Mellado-Valero A, Ferrer García JC, Herrera Ballester A, Labaig Rueda C. Effects of diabetes on the osseointegration of dental implants.
Med Oral Patol Oral Cir Bucal. 2007;12:E38-43.
PMid:17195826