Walter A, Winsauer H,
Marcé-Nogué J, Mojal S, Puigdollers A. Design characteristics, primary stability
and risk of fracture of orthodontic mini-implants: Pilot scan electron
microscope and mechanical studies. Med Oral Patol
Oral Cir Bucal. 2013 Sep 1;18 (5):e804-10.
doi:10.4317/medoral.18674
http://dx.doi.org/doi:10.4317/medoral.18674
1. Kong L, Hu K, Li D, Song Y, Yang J, Wu Z,
et al. Evaluation of the cylinder implant thread height and width: a
3-dimensional finite element analysis. Int J
Oral Maxillofac Implants.
2008;23:65-74. |
||||
|
||||
2. Hong J, Lim YJ, Park SO. Quantitative biomechanical analysis of the
influence of the cortical bone and implant length on primary stability. Clin Oral Implants Res. 2012;23:1193-7. |
||||
|
||||
3. Wilmes B , Rademacher
C, Olthoff G, Drescher D.
Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop. 2006;67:162-74. |
||||
|
||||
4. Shah AH, Behrents RG, Kim KB, Kyung HM, Buschang PH. Effects of screw and host factors on
insertion torque and pullout strength. Angle Orthod. 2012;82:603-10. |
||||
|
||||
5. Chapman JR, Harrington RM, Lee KM, Anderson PA, Tencer
AF, Kowalski D. Factors affecting the pullout strength of cancellous
bone screws. J Biomech
Eng. 1996;118:391-8. |
||||
|
||||
6. Song YY, Cha JY, Hwang CJ. Mechanical specifications of various
orthodontic mini-screws in relation to artificial cortical bone thickness. Angle Orthod. 2007;77:979-85. |
||||
|
||||
7. Jolley T, Chung C. Peak torque values at
fracture of orthodontic miniscrews. J Clin Orthod.
2007;41:326-8. |
||||
|
||||
8. Kim YK, Kim YJ, Yun PY, Kim JW. Effects of the taper shape, dual-thread, and
length on the mechanical properties of mini-implants. Angle Orthod. 2009;79:908-14. |
||||
|
||||
9. Petrey JS, Saunders MM, Kluemper GT, Cunningham LL, Beeman
CS. Temporary anchorage device insertion variables: effects on retention.
Angle Orthod. 2010;80:446-53. |
||||
|
||||
10. Barros SE, Janson G, Chiqueto
K, Garib DG, Janson M.
Effect of mini-implant diameter on fracture risk and self-drilling efficacy.
Am J Orthod Dentofacial Orthop. 2011;140:e181-92. |
||||
|
||||
11. Florvaag
B, Kneuertz P, Lazar F, Koebke
J, Zöller E, Braumann B,
et al. Biomechanical properties of orthodontic miniscrews.
An in-vitro study. J Orofac Orthop.
2010;71:53-67. |
||||
|
||||
12. Lee NK, Baek SH. Effects of the diameter
and shape of orthodontic mini-implants on microdamage
to the cortical bone. Am J Orthod Dentofacial Orthop. 2010;138:8.e1-8. |
||||
|
||||
13. Cho KC, Baek SH. Effects of predrilling depth and implant shape on the mechanical
properties of orthodontic mini-implants during the insertion procedure. Angle Orthod. 2012;82:618-24. |
||||
|
||||
14. Rebaudi A, Laffi
N, Benedicenti S, Angiero
F, Romanos GE. Microcomputed
tomographic analysis of bone reaction at insertion
of orthodontic mini-implants in sheep. Int J
Oral Maxillofac Implants.
2011;26:1233-40. |
||||
|
||||
15. Cha JY, Takano-Yamamoto T, Hwang CJ. The effect of miniscrew taper morphology on insertion and removal
torque in dogs. Int J Oral Maxillofac Implants. 2010;25:777-83. |
||||
|
||||
16. Hong C, Lee H, Webster R, Kwak J, Wu BM,
Moon W. Stability comparison between commercially available mini-implants and
a novel design: part 1. Angle Orthod. 2011;81:692-9. |
||||
|
||||
17. Wilmes B, Drescher
D. Impact of bone quality, implant type, and implantation site preparation on
insertion torques of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Surg.
2011;40:697-703. |
||||
|
||||
18. Crismani AG, Bertl
MH, Celar AG, Bantleon
HP, Burstone CJ. Miniscrews
in orthodontic treatment: review and analysis of published clinical trials.
Am J Orthod Dentofacial Orthop. 2010;137:108-13. |
||||
|
||||
19. Chen Y, Kyung HM, Gao L, Yu WJ, Bae EJ, Kim SM. Mechanical properties of self-drilling
orthodontic micro-implants with different diameters. Angle Orthod. 2010;80:821-7. |
||||
|
||||
20. Togni
F, Baras F, Ribas Mde O,
Taha MO. Histomorphometric analysis of bone tissue
repair in rabbits after insertion of titanium screws under different torque. Acta Cir Bras. 2011;26:261-6. |
||||
|
||||
21. Motoyoshi M, Hirabayashi
M, Uemura M, Shimizu N. Recommended placement torque
when tightening an orthodontic mini-implant. Clin
Oral Implants Res. 2006;17:109-14. |
||||
|
||||
22. Motoyoshi M, Yoshida T, Ono A, Shimizu
N. Effect of cortical bone thickness and implant placement torque on
stability of orthodontic mini-implants. Int J
Oral Maxillofac Implants.
2007;22:779-84. |
||||
|
||||
23. McManus MM, Qian F, Grosland
NM, Marshall SD, Southard TE. Effect of miniscrew
placement torque on resistance to miniscrew
movement under load. Am J Orthod Dentofacial Orthop. 2011;140:e93-8. |
||||
|
||||
24. Suzuki EY, Suzuki B. Placement and removal torque values of
orthodontic miniscrew implants. Am J Orthod Dentofacial Orthop. 2011;139:669-78. |
||||
|
||||
25. Migliorati M, Signori A, Silvestrini-Biavati A. Temporary anchorage device
stability: an evaluation of thread shape factor. Eur
J Orthod. 2012;34:582-6. |
||||
|
||||
26. Mischkowski RA, Kneuertz
P, Florvaag B, Lazar F, Koebke
J, Zöller JE. Biomechanical comparison of four
different miniscrew types for skeletal anchorage in
the mandibulo-maxillary area. Int
J Oral and Maxillofac Surg. 2008;37:948-54. |
||||
|
||||
27. Pithon
MM, Nojima MG, Nojima LI.
In
vitro evaluation of insertion and removal torques of orthodontic
mini-implants. Int J Oral Maxillofac
Surg. 2011;40:80-5. |
||||
|
||||
28. Schätzle M, Männchen
R, Zwahlen M, Lang NP. Survival and failure rates
of orthodontic temporary anchorage devices: a systematic review. Clin Oral Implants Res. 2009;20:1351-9. |
||||
|
||||
29. Ludwig B, Glas B, Bowman SJ, Drescher D, Wilmes B. Miniscrew-supported Class III treatment with the Hybrid
RPE Advancer. J Clin
Orthod. 2010;44:533-9. |