Moscoso S, Pineda K, Basilio J, Alvarado C, Roig M, Duran-Sindreu F. Evaluation of Dentaport
ZX and Raypex 6 electronic apex locators: An in vivo
study. Med Oral Patol Oral
Cir Bucal. 2014 Mar 1;19 (2):e202-5.
doi:10.4317/medoral.19114
http://dx.doi.org/doi:10.4317/medoral.19114
1.
American Association of Endodontists. Glossary of
Endodontic Terms. 7th edn.
Chicago: AAE; 2003. |
|
|
|
2. Ricucci D. Apical limit of root canal instrumentation and
obturation, part 1. Literature review. Int Endod J 1998;31:384-93. |
|
|
|
3. Ricucci D, Langeland K. Apical
limit of root canal instrumentation and obturation,
part 2. Histological study. Int Endod
J 1998;31:394-409. |
|
|
|
4. Sjögren U, Hagglund B, Sundqvist G, Wing K. Factors affecting the long-term
results of endodontic treatment. J Endod 1990;16:498-504. |
|
|
|
5. ElAyouti A, Weiger R, Löst C. Frequency of overinstrumentation
with an acceptable radiographic working length. J Endod 2001;27:49-52. |
|
|
|
6. ElAyouti A, Weiger R, Löst C. The ability of Root ZX apex locator to reduce the
frequency of overestimated radiographic working length. J Endod 2002;28:116-9. |
|
|
|
7. Tselnik M, Baumgartner JC, Marshall JG. An evaluation of
Root ZX and Elements Diagnostic Apex Locators. J Endod 2005;31:507-9. |
|
|
|
8. Cianconi L, Angotti V, Felici R, Conte G, Mancini M. Accuracy of three
electronic apex locators compared with digital radiography: an ex vivo study.
J Endod 2010;36:2003-7. |
|
|
|
9.
Kobayashi C, Suda H. New electronic canal measuring
device based on the ratio method. J Endod 1994;20:111-4. |
|
|
|
10. de Vasconcelos BC, do Vale TM,
de Menezes AS, Pinheiro-Junior
EC, Vivacqua-Gomes N, Bernardes
RA, Hungaro et al. An ex vivo comparison of root canal length
determination by three electronic apex locators at positions short of the
apical foramen. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-61. |
|
|
|
11. Dummer PM, McGinn JH, Rees DG.
The position and topography of the apical canal constriction and apical
foramen. Int Endod J;1984:17:192-8. |
|
|
|
12. Lee
SJ, Nam KC, Kim YJ, Kim DW. Clinical accuracy of a new apex locator with an
automatic compensation circuit. J Endod 2002;28:706-9. |
|
|
|
13. Martínez-Lozano MA, Forner-Navarro
L, Sánchez-Cortés JL, Llena-Puy
C. Methodological considerations in the determination of working length. Int Endod J 2001;34:371-6. |
|
|
|
14. Stöber EK, Duran-Sindreu F, Mercadé M, Vera J, Bueno R, Roig M. An evaluation of Root ZX and iPex
Apex Locators: an in vivo study. J Endod 2011;37:607-10. |
|
|
|
15. Stöber EK, de Ribot J, Mercadé M, Vera J, Bueno R, Roig M, Duran-Sindreu F. An evaluation
of the Raypex 5 and the Mini Apex Locator. An in
vivo study. J Endod 2011;37:1349-52. |
|
|
|
16. Duran-Sindreu
F, Stöber EK, Mercadé M,
Vera J, García M, Bueno R et al. Comparison of in vivo and In vitro readings when
testing the accuracy of the Root ZX Apex Locator. J Endod 2012;38:236-9. |
|
|
|
17. Meares WA, Steiman HR. The
influence of sodium hypochlorite irrigation on the accuracy of the Root ZX
electronic apex locator. J Endod
2002;28:595-8. |
|
|
|
18. D'Assunçăo
FL, Albuquerque DS, Salazar-Silva JR, Dos Santos VC, Sousa JCN. Ex vivo evaluation of the
accuracy and coefficient of repeatability of three electronic apex locators
using a simple mounting model: a preliminary report. Int Endod J 2010;43:269-74. |
|
|
|
19. Jakobson SJ, Westpalhen VPD, da Silva Neto UX, Fariniuk LF, Picoli F, Carneiro E. The accuracy in the control of the apical
extent of rotary canal instrumentation using Root ZX and ProTaper
instruments: an in vivo study. J Endod 2008;34:1342-5. |
|
|
|
20. Wrbas KT, Ziegler AA, Altenburger
MJ, Schirrmeister JF. In vivo comparison of working
length determination with two electronic apex locators. Int Endod J 2007;40:133-8. |
|
|
|
21. D'Assunçăo
FL, de Albuquerque DS, de Queiroz Ferreira LC. The ability of two apex
locators to locate the apical foramen: an in vitro study. J Endod 2006;32:560-2. |
|
|
|
22. Felippe
WT, Felippe MCS, Reyes Carmona J, Crozoe ́ FCI, Alvisi BB. Ex vivo evaluation of the
ability of the ROOT ZX II to locate the apical foramen and to control the
apical extent of rotary canal instrumentation. Int Endod J
2008;41:502-7. |
|
|
|
23. Pagavino G, Pace R, Bacceti T.
A SEM study of in vivo accuracy of the Root ZX electronic apex locator. J Endod 1998;24:438-41. |
|
|
|
24.
Mancini M, Felici R, Conte G, Constantini
M, Cianconi L. Accuracy of three electronic apex
locators in anterior and posterior teeth: An ex vivo study. J Endod 2011;37:684-7. |
|
|
|
25. Ding
J, Gutmann JL, Fan B, Lu Y, Chen H. Investigation
of apex locators and related morphological factors. J Endod 2010;36:1399-403. |
|
|
|
26. Stein
TJ, Corcoran JF, Zillich RM. Influence of the major
and minor foramen diameters on apical electronic probe measurements. J Endod 1990;16:520-2. |