Peñarrocha-Oltra D, Agustín-Panadero R, Bagán L, Giménez B, Peñarrocha MA. Impression of multiple implants using photogrammetry:  Des-cription of technique and case presentation.. Med Oral Patol Oral Cir Bucal. 2014 Jul 1;19 (4):e366-71.

 

 

doi:10.4317/medoral.19365

http://dx.doi.org/doi:10.4317/medoral.19365

 

 

1. Wee AG, Aquilino SA, Schneider RL. Strategies to achieve fit in implant prosthodontics: a review of the literature. Int J Prosthodont. 1999;12:167-78.

 

2. Heckmann SM, Karl M, Wichmann MG, Winter W, Graef F, Taylor TD. Cement fixation and screw retention: parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures. Clin Oral Implants Res. 2004;15:466-73.
http://dx.doi.org/10.1111/j.1600-0501.2004.01027.x

 

3. Windhorn RJ, Gunnell TR. A simple open-tray implant impression technique. J Prosthet Dent. 2006;96:220-1.
http://dx.doi.org/10.1016/j.prosdent.2006.07.009

 

4. Akça K, Cehreli MC. Accuracy of 2 impression techniques for ITI implants. The Int J Oral Maxillofac Implants. 2004;19:517-23.

 

5. Cehreli MC, Akça K. Impression techniques and misfit-induced strains on implant-supported superstructures: an in vitro study. Int J Periodontics Restorative Dent. 2006;26:379–85.

 

6. Lee H, So JS, Hochstedler JL, Ercoli C. The accuracy of implant impressions: a systematic review. J Prosthet Dent. 2008;100:285-91.
http://dx.doi.org/10.1016/S0022-3913(08)60208-5

 

7. Kachalia PR, Geissberger MJ. Dentistry a la carte: in-office CAD/CAM technology. J Calif Dent Assoc. 2010;38:323-30.

 

8. Jemt T, Rubenstein JE, Carlsson L, Lang BR. Measuring fit at the implant prosthodontic interface. J Prosthet Dent. 1996;75:314-25.
http://dx.doi.org/10.1016/S0022-3913(96)90491-6

 

9. Rubio Serrano M, Albalat Estela S, Pe-arrocha Diago M, Pe-arrocha Diago M. Software applied to oral implantology: update. Med Oral Patol Oral Cir Bucal. 2008;13:e661-5.

 

10. Freedman M, Quinn F, O'Sullivan M. Single unit CAD/CAM restorations: a literature review. J Ir Dent Assoc. 2007;53:38-45.

 

11. Persson ASK, Andersson M, Odén A, Sandborgh-Englund G. Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology. Dent Mater. 2008;24:1123-30.
http://dx.doi.org/10.1016/j.dental.2008.01.008

 

12. Park J-I, Yoon T-H. A three-dimensional image-superimposition CAD/CAM technique to record the position and angulation of the implant abutment screw access channel. J Prosthet Dent. 2013;109:57-60.
http://dx.doi.org/10.1016/S0022-3913(13)60013-X

 

13. Thali MJ, Braun M, Wirth J, Vock P, Dirnhofer R. 3D surface and body documentation in forensic medicine: 3-D/CAD Photogrammetry merged with 3D radiological scanning. J Forensic Sci. 2003;48:1356-65.

 

14. Aroeira RMC, Leal JS, De Melo Pertence AE. New method of scoliosis assessment: preliminary results using computerized photogrammetry. Spine. 2011;36:1584-91.
http://dx.doi.org/10.1097/BRS.0b013e3181f7cfaa

 

15. Goellner M, Schmitt J, Karl M, Wichmann M, Holst S. Photogrammetric measurement of initial tooth displacement under tensile force. Med Eng Phys. 2010;32:883-8.
http://dx.doi.org/10.1016/j.medengphy.2010.06.004

 

16. Kau CH, Kamel SG, Wilson J, Wong ME. New method for analysis of facial growth in a pediatric reconstructed mandible. Am J Orthod Dentofacial Orthop. 2011;139:e285-90.
http://dx.doi.org/10.1016/j.ajodo.2009.03.054

 

17. Deli R, Gioia E Di, Galantucci LM, Percoco G. Accurate facial morphologic measurements using a 3-camera photogrammetric method. J Craniofac Surg. 2011;22:54-9.
http://dx.doi.org/10.1097/SCS.0b013e3181f6c4a1

 

18. Marini I, Bonetti GA, Achilli V, Salemi G. A photogrammetric technique for the analysis of palatal three-dimensional changes during rapid maxillary expansion. Eur J Orthod. 2007;29:26-30.
http://dx.doi.org/10.1093/ejo/cji069

 

19. Frisardi G, Chessa G, Barone S, Paoli A, Razionale A, Frisardi F. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery. BMC Med Imaging. 2011;11:5. doi: 10.1186/1471-2342-11-5.
http://dx.doi.org/10.1186/1471-2342-11-5

 

20. Lie A, Jemt T. Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures. Clin Oral Implants Res. 1994;5:30-6.
http://dx.doi.org/10.1034/j.1600-0501.1994.050104.x

 

21. Jemt T, Bäck T, Petersson A. Photogrammetry--an alternative to conventional impressions in implant dentistry? A clinical pilot study. Int J Prosthodont. 1999;12:363-8.

 

22. Haselhuhn K, Marotti J, Tortamano P, Weiss C, Suleiman L, Wolfart S. Assessment of the stress transmitted to dental implants connected to screw-retained bars using different casting techniques. J Oral Implantol. 2012;27:[Epub ahead of print].

 

23. Rubenstein JE, Ma T. Comparison of interface relationships between implant components for laser-welded titanium frameworks and standard cast frameworks. Int J Oral Maxillofac Implants. 1999;14:491-5.

 

24. Del'Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo F de A. Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implants. 2008;23:226-36.

 

25. Eliasson A, Ortorp A. The accuracy of an implant impression technique using digitally coded healing abutments. Clin Implant Dent Relat Res. 2012;14 Suppl 1:e30-8.
http://dx.doi.org/10.1111/j.1708-8208.2011.00344.x

 

26. Fuster-Torres MA, Albalat-Estela S, Alca-iz-Raya M, Pe-arrocha-Diago M. CAD / CAM dental systems in implant dentistry: update. Med Oral Patol Oral Cir Bucal. 2009;14:e141-5.

 

27. Kim S, Nicholls JI, Han C-H, Lee K-W. Displacement of implant components from impressions to definitive casts. Int J Oral Maxillofac Implants. 2006;21:747-55.

 

28. Abduo J, Bennani V, Waddell N, Lyons K, Swain M. Assessing the fit of implant fixed prostheses: a critical review. Int J Oral Maxillofac Implants. 2010;25:506-15.