Agustín-Panadero R, Serra-Pastor B, Roig-Vanaclocha
A, Román-Rodriguez JL, Fons-Font
A. Mechanical behavior
of provisional implant prosthetic abutments. Med
Oral Patol Oral Cir Bucal.
2015 Jan 1;20 (1):e94-102.
doi:10.4317/medoral.19958
http://dx.doi.org/doi:10.4317/medoral.19958
1. Bruno V, Badino
M, Sacco R, Catapano S. The
use of a prosthetic template
to maintain the papilla in the esthetic zone for immediate implant placement by means of a radiographic procedure. J Prosthet Dent. 2012;108:394-7. |
|
|
|
2. Priest
G. Esthetic potential of
single-implant provisional restorations:
selection criteria of available alternatives. J Esthet Restor Dent. 2006;18:326-339. |
|
|
|
3. Santosa
RE. Provisional restoration options
in implant dentistry. Aust Dent J. 2007; 52:234-42. |
|
|
|
4. Buser
D, Martin W, Belser UC. Optimizing
esthetics for implant restorations in the anterior maxilla: anatomic and surgical considerations. Int J Oral Maxillofac Implants. 2004;19:43-61. |
|
|
|
5. Su H, Gonzalez-Martin
O, Weisgold A, Lee E. Considerations
of implant abutment and crown contour: critical contour and subcritical contour. Int J Periodontics Restorative Dent. 2010;30:335-43. |
|
|
|
6. Manicone
PF, Raffaelli L, Ghassemian
M, D'Addona A. Soft and Hard Tissue Management in Implant Therapy-Part II: Prosthetic Concepts. Int J Biomater. 2012;2012:356817. |
|
|
|
7. Crespi
R, Capparè P, Gherlone E,
Romanos G. Immediate provisionalization
of dental implants placed in fresh
extraction sockets using
a flapless technique. Int J Periodontics Restorative Dent. 2012;32:29-37. |
|
|
|
8. Ferrario
VF, Sforza C, Serrao G, Dellavia C, Tartaglia GM. Single
tooth bite forces in healthy young adults. J Oral Rehabil. 2004;31:18-22. |
|
|
|
9. Nothdurft
FP, Doppler KE, Erdelt
KJ, Knauber AW, Pospiech
PR. Fracture behavior of straight
or angulated zirconia implant abutments supporting anterior
single crowns. Clin Oral Investig. 2011;15:157-63. |
|
|
|
10. Nothdurft
FP, Doppler KE, Erdelt
KJ, Knauber AW, Pospiech
PR. Influence of artificial aging
on the load-bearing capability of straight or angulated
zirconia abutments in implant/tooth-supported fixed partial dentures. Int J Oral Maxillofac Implants. 2010;25:991-8. |
|
|
|
11. Truninger
TC, Stawarczyk B, Leutert
CR, Sailer TR, Hämmerle
CH, Sailer I. Bending moments of zirconia and titanium abutments with internal and
external implant-abutment connections after aging and chewing simulation. Clin Oral Implants Res. 2012;23:12-8. |
|
|
|
12. Martínez-Rus F, Ferreiroa A, Özcan M, Bartolomé
JF, Pradíes G. Fracture resistance
of crowns cemented on titanium and zirconia implant abutments: a comparison of monolithic versus manually veneered all-ceramic systems. Int J Oral Maxillofac Implants. 2012;27:1448-55. |
|
|
|
13. Rack T, Zabler
S, Rack A, Riesemeier H, Nelson K. An in vitro pilot study of abutment stability during loading in new and fatigue-loaded
conical dental implants using synchrotron-based radiography. Int J Oral Maxillofac Implants. 2013;28:44-50. |
|
|
|
14. Sannino
G, Barlattani A. Mechanical
evaluation of an implant-abutment self-locking taper connection: finite element analysis and experimental tests.
Int J Oral Maxillofac Implants. 2013;28:17-26. |
|
|
|
15. Steinebrunner
L, Wolfart S, Ludwig K, Kern M. Implant-abutment
interface design affects
fatigue and fracture strength of implants. Clin Oral Implants Res. 2008;19:1276-84. |
|
|
|
16. Santing
HJ, Meijer HJ, Raghoebar
GM, Özcan M. Fracture strength
and failure mode of maxillary implant-supported
provisional single crowns: a comparison
of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments. Clin Implant Dent Relat Res. 2012;14:882-9. |