Albertini M, Fernandez-Yague M, L‡zaro P, Herrero-Climent M, Rios-Santos JV, Bullon P, Gil FJ. Advances in surfaces and osseointegration in implantology. Biomimetic surfaces. Med Oral Patol Oral Cir Bucal. 2015 May 1;20 (3):e316-25.  

 

 

doi:10.4317/medoral.20353

http://dx.doi.org/doi:10.4317/medoral.20353

 

 

1. Blanes RJ, Bernard JP, Blanes ZM, Belser UC. A 10-year prospective study of ITI dental implants placed in the posterior region. I: Clinical and radiographic results. Clin Oral Implants Res. 2007;18:699-706.
http://dx.doi.org/10.1111/j.1600-0501.2006.01306.x

 

2. Simonis P, Dufour T, Tenenbaum H. Long-term implant survival and success: a 10-16-year follow-up of non-submerged dental implants. Clin Oral Implants Res. 2010;21:772-7.
http://dx.doi.org/10.1111/j.1600-0501.2010.01912.x

 

3. BrŒnemark PI, Hansson BO, Adell R, Breine U, Lindstršm J, HallŽn O, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1-132.

 

4. Schroeder A, van der Zypen E, Stich H, Sutter F. The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces. J Maxillofac Surg. 1981;9:15-25.
http://dx.doi.org/10.1016/S0301-0503(81)80007-0

 

5. Johansson C, Albrektsson T. Integration of screw implants in the rabbit: a 1-year follow-up of removal torque of titanium implants. Int J Oral Maxillofac Implants. 1987;2:69-75.

 

6. Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res. 1991;25:889-902.
http://dx.doi.org/10.1002/jbm.820250708

 

7. Abrahamsson I, Berglundh T, Linder E, Lang NP, Lindhe J. Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog. Clin Oral Implants Res. 2004;15:381-92.
http://dx.doi.org/10.1111/j.1600-0501.2004.01082.x

 

8. Strub JR, Jurdzik BA, Tuna T. Prognosis of immediately loaded implants and their restorations: a systematic literature review. J Oral Rehabil. 2012;39:704-17.
http://dx.doi.org/10.1111/j.1365-2842.2012.02315.x

 

9. Avila G, Misch K, Galindo-Moreno P, Wang HL. Implant surface treatment using biomimetic agents. Implant Dent. 2009;18:17-26.
http://dx.doi.org/10.1097/ID.0b013e318192cb7d

 

10. Pattanayak DK, Yamaguchi S, Matsushita T, Kokubo T. Nanostructured positively charged bioactive TiO2 layer formed on Ti metal by NaOH, acid and heat treatments. J Mater Sci Mater Med. 2011;22:1803-12.
http://dx.doi.org/10.1007/s10856-011-4372-x

 

11. Pegueroles M, Tonda-Turo C, Planell JA, Gil FJ, Aparicio C. Adsorption of fibronectin, fibrinogen, and albumin on TiO2: time-resolved kinetics, structural changes, and competition study. Biointerphases. 2012;7:48.
http://dx.doi.org/10.1007/s13758-012-0048-4

 

12. O'Brien CP, Stuart SJ, Bruce DA, Latour RA. Modeling of peptide adsorption interactions with a poly(lactic acid) surface. Langmuir. 2008;24:14115-24.
http://dx.doi.org/10.1021/la802588n

 

13. Nygren H, Tengvall P, Lundstršm I. The initial reactions of TiO2 with blood. J Biomed Mater Res. 1997;34:487-92.
http://dx.doi.org/10.1002/(SICI)1097-4636(19970315)34:4<487::AID-JBM9>3.0.CO;2-G

 

14. Chatakun P, Nœ-ez-Toldrˆ R, D’az L—pez EJ, Gil-Recio C, Mart’nez-Sarrˆ E, Hern‡ndez-Alfaro F, et al. The effect of five proteins on stem cells used for osteoblast differentiation and proliferation: a current review of the literature. Cell Mol Life Sci. 2014;71:113-42.
http://dx.doi.org/10.1007/s00018-013-1326-0

 

15. Pegueroles M, Aparicio C, Bosio M, Engel E, Gil FJ, Planell JA, et al. Spatial organization of osteoblast fibronectin matrix on titanium surfaces: effects of roughness, chemical heterogeneity and surface energy. Acta Biomater. 2010;6:291-301.
http://dx.doi.org/10.1016/j.actbio.2009.07.030

 

16. Rivera-Chacon DM, Alvarado-Velez M, Acevedo-Morantes CY, Singh SP, Gultepe E, Nagesha D, et al. Fibronectin and vitronectin promote human fetal osteoblast cell attachment and proliferation on nanoporous titanium surfaces. J Biomed Nanotechnol. 2013;9:1092-7.
http://dx.doi.org/10.1166/jbn.2013.1601

 

17. Petrie TA, Reyes CD, Burns KL, Garc’a AJ. Simple application of fibronectin-mimetic coating enhances osseointegration of titanium implants. J Cell Mol Med. 2009;13:2602-12.
http://dx.doi.org/10.1111/j.1582-4934.2008.00476.x

 

18. Aliuos P, Sen A, Reich U, Dempwolf W, Warnecke A, Hadler C, et al. Inhibition of fibroblast adhesion by covalently immobilized protein repellent polymer coatings studied by single cell force spectroscopy. J Biomed Mater Res A. Epub ahead of print. 2013.

 

19. Ramaglia L, Postiglione L, Di Spigna G, Capece G, Salzano S, Rossi G. Sandblasted-acid-etched titanium surface influences in vitro the biological behavior of SaOS-2 human osteoblast-like cells. Dent Mater J. 2011;30:183-92.
http://dx.doi.org/10.4012/dmj.2010-107

 

20. Davies JE. Mechanisms of endosseous integration. Int J Prosthodont. 1998;11:391-401.

 

21. Osborn JF, Newesely H. The material science of calcium phosphate ceramics. Biomaterials. 1980;1:108-11.
http://dx.doi.org/10.1016/0142-9612(80)90009-5

 

22. Davies JE. In vitro modeling of the bone/implant interface. Anat Rec. 1996;245:426-45.
http://dx.doi.org/10.1002/(SICI)1097-0185(199606)245:2<426::AID-AR21>3.0.CO;2-Q

 

23. Berglundh T, Abrahamsson I, Lang NP, Lindhe J. De novo alveolar bone formation adjacent to endosseous implants. Clin Oral Implants Res. 2003;14:251-62.
http://dx.doi.org/10.1034/j.1600-0501.2003.00972.x

 

24. Herrero-Climent M, L‡zaro P, Vicente Rios J, Lluch S, MarquŽs M, Guillem-Mart’ J, et al. Influence of acid-etching after grit-blasted on osseointegration of titanium dental implants: in vitro and in vivo studies. J Mater Sci Mater Med. 2013;24:2047-55.
http://dx.doi.org/10.1007/s10856-013-4935-0

 

25. Frost HM. A 2003 update of bone physiology and Wolff's Law for clinicians. Angle Orthod. 2004;74:3-15.

 

26. Adell R, Lekholm U, Rockler B, BrŒnemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg.1981;10:387-416.
http://dx.doi.org/10.1016/S0300-9785(81)80077-4

 

27. Albrektsson T, Wennerberg A. Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them. Int J Prosthodont. 2004;17:536-43.

 

28. Aparicio C, Padr—s A, Gil FJ. In vivo evaluation of micro-rough and bioactive titanium dental implants using histometry and pull-out tests. J Mech Behav Biomed Mater. 2011;4:1672-82.
http://dx.doi.org/10.1016/j.jmbbm.2011.05.005

 

29. Gao SS, Zhang YR, Zhu ZL, Yu HY. Micromotions and combined damages at the dental implant/bone interface. Int J Oral Sci. 2012;4:182-8.
http://dx.doi.org/10.1038/ijos.2012.68

 

30. Ogilvie A, Frank RM, BenquŽ EP, Gineste M, Heughebaert M, Hemmerle J. The biocompatibility of hydroxyapatite implanted in the human periodontium. J Periodontal Res. 1987;22:270-83.
http://dx.doi.org/10.1111/j.1600-0765.1987.tb01585.x

 

31. Meffert RM. Ceramic-coated implant systems. Adv Dent Res. 1999;13:170-2.
http://dx.doi.org/10.1177/08959374990130010701

 

32. Lee JJ, Rouhfar L, Beirne OR. Survival of hydroxyapatite-coated implants: a meta-analytic review. J Oral Maxillofac Surg. 2000;58:1372-9.
http://dx.doi.org/10.1053/joms.2000.18269

 

33. Liu Y, de Groot K, Hunziker EB. Osteoinductive implants: The mise-en-scene for drug-bearing biomimetic coatings. Ann Biomed Eng. 2004;32:398-406.
http://dx.doi.org/10.1023/B:ABME.0000017536.10767.0f

 

34. Yang Y, Kim KH, Ong JL. A review on calciumphosphate coatings produced using a sputtering process. An alternative to plasma spraying. Biomaterials. 2005;26:327-37.
http://dx.doi.org/10.1016/j.biomaterials.2004.02.029

 

35. Kim H, Camata RP, Lee S, Rohrer GS, Rollett AD, VohraYK. Crystallographic texture in pulsed laser deposited hydroxyapatite bioceramic coatings. Acta Mater. 2007;55:131-9.
http://dx.doi.org/10.1016/j.actamat.2006.08.008

 

36. Aparicio C, Manero JM, Conde F, Pegueroles M, Planell JA, Vallet-Reg’ M, et al. Acceleration of apatite nucleation on microrough bioactive titanium for bone-replacing implants. J Biomed Mater Res A. 2007;82:521-9.
http://dx.doi.org/10.1002/jbm.a.31164

 

37. Gil FJ, Manzanares N, Badet A, Aparicio C, Ginebra MP. Biomimetic treatment on dental implants for short-term bone regeneration. Clin Oral Investig. 2014;18:59-66.
http://dx.doi.org/10.1007/s00784-013-0953-z

 

38. Morris HF, Ochi S, Spray JR, Olson JW. Periodontal-type measurements associated with hydroxyapatite-coated and non-HA-coated implants: uncovering to 36 months. Ann Periodontol. 2000;5:56-67.
http://dx.doi.org/10.1902/annals.2000.5.1.56

 

39. Takemoto M, Fujibayashi S, Neo M, Suzuki J, Kokubo T, Nakamura T. Mechanical properties and osteoconductivity of porous bioactive titanium. Biomaterials. 2005;26:6014-23.
http://dx.doi.org/10.1016/j.biomaterials.2005.03.019