Falisi G, Severino M, Rastelli C, Bernardi S, Caruso S, Galli M, Lamazza L, Di Paolo C. The effects of surgical preparation techniques and implant macro-geometry on primary stability: An in vitro study. Med Oral Patol Oral Cir Bucal. 2017 Mar 1;22 (2):e201-6.

 

 

doi:10.4317/medoral.21286

http://dx.doi.org/doi:10.4317/medoral.21286

 

 

1. Mellado-Valero A, Ferrer-Garc’a JC, Calvo-Catal‡ J, Labaig-Rueda C. Implant treatment in patients with osteoporosis. Med Oral Patol Oral Cir Bucal. 2010;15:e52-7.

 

2. Mathieu V, Vayron R, Richard G, Lambert G, Naili S, Meningaud JP, et al. Biomechanical determinants of the stability of dental implants: influence of the bone-implant interface properties. J Biomech. 2014;47:3-13.
https://doi.org/10.1016/j.jbiomech.2013.09.021

 

3. Zonfrillo G, Matteoli S, Ciabattini A, Dolfi M, Lorenzini L, Corvi A. Analysis and comparison of clutch techniques of two dental implants. J Mech Behav Biomed Mater. 2014;34C:1-7.
https://doi.org/10.1016/j.jmbbm.2014.01.017

 

4. Toyoshima T, Tanaka H, Ayukawa Y, Howashi M, Masuzaki T, Kiyosue T, et al. Primary Stability of a Hybrid Implant Compared with Tapered and Cylindrical Implants in an Ex Vivo Model. Clin Implant Dent Relat Res. 2015;17:950-6.
https://doi.org/10.1111/cid.12205

 

5. Guizzardi S, Galli C, Martini D, Belletti S, Tinti A, Raspanti M, et al. Different titanium surface treatment influences human mandibular osteoblast response. J Periodontol. 2004;75:273-82.
https://doi.org/10.1902/jop.2004.75.2.273

 

6. Franchi M, Bacchelli B, Giavaresi G, De Pasquale V, Martini D, Fini M, et al. Influence of different implant surfaces on peri-implant osteogenesis: Histomorphometric analysis in sheep. J Periodontol. 2007;78:879-88.
https://doi.org/10.1902/jop.2007.060280

 

7. Friberg B, Jemt T, Lekholm U. Early failures in 4,641 consecutively placed BrŒnemark dental implants: a study from stage 1 surgery to the connection of completed prostheses. Int J Oral Maxillofac Implants. 1991;6:142-6.

 

8. Herrmann I, Lekholm U, Holm S, Kultje C. Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures. Int J Oral Maxillofac Implants. 2005;20:220-30.

 

9. Coutant JC, Seguela V, Hauret L, Caix P, Ella B. Assessment of the correlation between implant stability and bone density by computed tomography and resonance frequency analysis in fresh cadavers. Int J Oral Maxillofac Implants. 2014;29:1264-70.

 

10. Jeong MA, Jung MK, Kim SG, Oh JS. Implant Stability Measurements in the Long-Term Follow-up of Dentis Implants: A Retrospective Study With Periotest. Implant Dent. 2015;24:263-6.
https://doi.org/10.1097/id.0000000000000239

 

11. Gehrke SA, Marin GW. Biomechanical evaluation of dental implants with three different designs: Removal torque and resonance frequency analysis in rabbits. Ann Anat. 2015;199:30-5.
https://doi.org/10.1016/j.aanat.2014.07.009

 

12. Oliscovicz NF, Shimano AC, Marcantonio Junior E, Lepri CP, Dos Reis AC. Analysis of primary stability of dental implants inserted in different substrates using the pullout test and insertion torque. Int J Dent. 2013;2013:194987.
https://doi.org/10.1155/2013/194987

 

13. Barfeie A, Wilson J, Rees J. Implant surface characteristics and their effect on osseointegration. Br Dent J. 2015;218:E9.
https://doi.org/10.1038/sj.bdj.2015.171

 

14. Moon SH, Um HS, Lee JK, Chang BS, Lee MK. The effect of implant shape and bone preparation on primary stability. J Periodontal Implant Sci. 2010;40:239-43.
https://doi.org/10.5051/jpis.2010.40.5.239

 

15. Laurito D, Lamazza L, Garreffa G, De Biase A. An alternative method to record rising temperatures during dental implant site preparation: a preliminary study using bovine bone. Ann Ist Super Sanita. 2010;46:405-10.

 

16. Valente ML, Lepri CP, dos-Reis AC. In vitro microstructural analysis of dental implants subjected to insertion torque and pullout test. Braz Dent J. 2014;25:343-5.
https://doi.org/10.1590/0103-6440201302402

 

17. Choi HH, Chung CH, Kim SG, Son MK. Reliability of 2 implant stability measuring methods in assessment of various periimplant bone loss: an in vitro study with the Periotest and Osstell Mentor. Implant Dent. 2014;23:1-6.
https://doi.org/10.1097/ID.0000000000000000

 

18. Rastelli C, Falisi G, Gatto R, Galli M, Saccone E, Severino M, et al. Implant stability in different techniques of surgical sites preparation: an in vitro study. Oral Implantol (Rome). 2014;7:33-9.
https://doi.org/10.11138/orl/2014.7.2.033

 

19. RozŽ J, Babu S, Saffarzadeh A, Gayet-Delacroix M, Hoornaert A, Layrolle P. Correlating implant stability to bone structure. Clin Oral Implants Res. 2009;20:1140-5.
https://doi.org/10.1111/j.1600-0501.2009.01745.x

 

20. Turkyilmaz I, Aksoy U, McGlumphy EA. Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data. Clin Implant Dent Relat Res. 2008;10:231-7.
https://doi.org/10.1111/j.1708-8208.2008.00084.x

 

21. Alghamdi H, Anand PS, Anil S. Undersized Implant Site Preparation to Enhance Primary Implant Stability in Poor Bone Density: A Prospective Clinical Study. J Oral Maxillofac Surg. 2011;69:e506-12.
https://doi.org/10.1016/j.joms.2011.08.007

 

22. Petrov SD, Xing Y, Khandelwal N, Drew HJ. A novel technique for osteotome internal sinus lifts with simultaneous placement of tapered implants to improve primary stability. J Oral Implantol. 2014;40:607-13.
https://doi.org/10.1563/AAID-JOI-D-13-00004

 

23. Krafft T, Graef F, Winter W, Wichmann M, Karl M. Use of osteotomes for implant bed preparation-effect on material properties of bone and primary implant stability. J Oral Implantol. 2013;39:241-7.
https://doi.org/10.1563/AAID-JOI-D-10-00187

 

24. Di Alberti L, Donnini F, Di Alberti C, Camerino M. A comparative study of bone densitometry during osseointegration: piezoelectric surgery versus rotary protocols. Quintessence Int. 2010;41:639-44.

 

25. Stacchi C, Vercellotti T, Torelli L, Furlan F, Di Lenarda R. Preparation Techniques: Twist Drills versus Piezosurgery. A Single-Blinded, Randomized, Controlled Clinical Trial. Clin Implant Dent Relat Res. 2013;15:188-97.
https://doi.org/10.1111/j.1708-8208.2011.00341.x

 

26. Preti G, Martinasso G, Peirone B, Navone R, Manzella C, Muzio G, et al. Cytokines and growth factors involved in the osseointegration of oral titanium implants positioned using piezoelectric bone surgery versus a drill technique: a pilot study in minipigs. J Periodontol. 2007;78:716-22.
https://doi.org/10.1902/jop.2007.060285

 

27. Cano J, Campo J. Bone implant sockets made using three different procedures: a stability study in dogs. J Clin Exp Dent. 2012;4:e217-20.
https://doi.org/10.4317/jced.50803

 

28. Yoon HG, Heo SJ, Koak JY, Kim SK, Lee SY. Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value. J Adv Prosthodont. 2011;3:10-5.
https://doi.org/10.4047/jap.2011.3.1.10

 

29. Rodrigo D, Aracil L, Martin C, Sanz M. Diagnosis of implant stability and its impact on implant survival: a prospective case series study. Clin Oral Implants Res. 2010;21:255-61.
https://doi.org/10.1111/j.1600-0501.2009.01820.x