Falisi G,
Severino M, Rastelli C, Bernardi S, Caruso S, Galli M, Lamazza L, Di Paolo C.
The effects of surgical preparation techniques and implant macro-geometry on
primary stability: An in vitro study. Med Oral Patol Oral Cir Bucal. 2017 Mar 1;22
(2):e201-6.
doi:10.4317/medoral.21286
http://dx.doi.org/doi:10.4317/medoral.21286
1.
Mellado-Valero A, Ferrer-Garca JC, Calvo-Catal J, Labaig-Rueda C. Implant
treatment in patients with osteoporosis. Med Oral Patol Oral Cir Bucal.
2010;15:e52-7. |
|
|
|
2.
Mathieu V, Vayron R, Richard G, Lambert G, Naili S, Meningaud JP, et al.
Biomechanical determinants of the stability of dental implants: influence of
the bone-implant interface properties. J Biomech. 2014;47:3-13. |
|
|
|
3.
Zonfrillo G, Matteoli S, Ciabattini A, Dolfi M, Lorenzini L, Corvi A.
Analysis and comparison of clutch techniques of two dental implants. J Mech
Behav Biomed Mater. 2014;34C:1-7. |
|
|
|
4.
Toyoshima T, Tanaka H, Ayukawa Y, Howashi M, Masuzaki T, Kiyosue T, et al.
Primary Stability of a Hybrid Implant Compared with Tapered and Cylindrical
Implants in an Ex Vivo Model. Clin Implant Dent Relat Res. 2015;17:950-6. |
|
|
|
5.
Guizzardi S, Galli C, Martini D, Belletti S, Tinti A, Raspanti M, et al.
Different titanium surface treatment influences human mandibular osteoblast
response. J Periodontol. 2004;75:273-82. |
|
|
|
6.
Franchi M, Bacchelli B, Giavaresi G, De Pasquale V, Martini D, Fini M, et al.
Influence of different implant surfaces on peri-implant osteogenesis:
Histomorphometric analysis in sheep. J Periodontol. 2007;78:879-88. |
|
|
|
7.
Friberg B, Jemt T, Lekholm U. Early failures in 4,641 consecutively placed
Brnemark dental implants: a study from stage 1 surgery to the connection of
completed prostheses. Int J Oral Maxillofac Implants. 1991;6:142-6. |
|
|
|
8.
Herrmann I, Lekholm U, Holm S, Kultje C. Evaluation of patient and implant
characteristics as potential prognostic factors for oral implant failures.
Int J Oral Maxillofac Implants. 2005;20:220-30. |
|
|
|
9.
Coutant JC, Seguela V, Hauret L, Caix P, Ella B. Assessment of the
correlation between implant stability and bone density by computed tomography
and resonance frequency analysis in fresh cadavers. Int J Oral Maxillofac
Implants. 2014;29:1264-70. |
|
|
|
10.
Jeong MA, Jung MK, Kim SG, Oh JS. Implant Stability Measurements in the
Long-Term Follow-up of Dentis Implants: A Retrospective Study With Periotest.
Implant Dent. 2015;24:263-6. |
|
|
|
11.
Gehrke SA, Marin GW. Biomechanical evaluation of dental implants with three
different designs: Removal torque and resonance frequency analysis in
rabbits. Ann Anat. 2015;199:30-5. |
|
|
|
12.
Oliscovicz NF, Shimano AC, Marcantonio Junior E, Lepri CP, Dos Reis AC.
Analysis of primary stability of dental implants inserted in different
substrates using the pullout test and insertion torque. Int J Dent.
2013;2013:194987. |
|
|
|
13.
Barfeie A, Wilson J, Rees J. Implant surface characteristics and their effect
on osseointegration. Br Dent J. 2015;218:E9. |
|
|
|
14.
Moon SH, Um HS, Lee JK, Chang BS, Lee MK. The effect of implant shape and
bone preparation on primary stability. J Periodontal Implant Sci.
2010;40:239-43. |
|
|
|
15.
Laurito D, Lamazza L, Garreffa G, De Biase A. An alternative method to record
rising temperatures during dental implant site preparation: a preliminary
study using bovine bone. Ann Ist Super Sanita. 2010;46:405-10. |
|
|
|
16.
Valente ML, Lepri CP, dos-Reis AC. In vitro microstructural analysis of
dental implants subjected to insertion torque and pullout test. Braz Dent J.
2014;25:343-5. |
|
|
|
17.
Choi HH, Chung CH, Kim SG, Son MK. Reliability of 2 implant stability
measuring methods in assessment of various periimplant bone loss: an in vitro
study with the Periotest and Osstell Mentor. Implant Dent. 2014;23:1-6. |
|
|
|
18.
Rastelli C, Falisi G, Gatto R, Galli M, Saccone E, Severino M, et al. Implant
stability in different techniques of surgical sites preparation: an in vitro
study. Oral Implantol (Rome). 2014;7:33-9. |
|
|
|
19.
Roz J, Babu S, Saffarzadeh A, Gayet-Delacroix M, Hoornaert A, Layrolle P.
Correlating implant stability to bone structure. Clin Oral Implants Res.
2009;20:1140-5. |
|
|
|
20.
Turkyilmaz I, Aksoy U, McGlumphy EA. Two alternative surgical techniques for
enhancing primary implant stability in the posterior maxilla: a clinical
study including bone density, insertion torque, and resonance frequency
analysis data. Clin Implant Dent Relat Res. 2008;10:231-7. |
|
|
|
21.
Alghamdi H, Anand PS, Anil S. Undersized Implant Site Preparation to Enhance
Primary Implant Stability in Poor Bone Density: A Prospective Clinical Study.
J Oral Maxillofac Surg. 2011;69:e506-12. |
|
|
|
22.
Petrov SD, Xing Y, Khandelwal N, Drew HJ. A novel technique for osteotome
internal sinus lifts with simultaneous placement of tapered implants to
improve primary stability. J Oral Implantol. 2014;40:607-13. |
|
|
|
23.
Krafft T, Graef F, Winter W, Wichmann M, Karl M. Use of osteotomes for
implant bed preparation-effect on material properties of bone and primary
implant stability. J Oral Implantol. 2013;39:241-7. |
|
|
|
24. Di
Alberti L, Donnini F, Di Alberti C, Camerino M. A comparative study of bone
densitometry during osseointegration: piezoelectric surgery versus rotary
protocols. Quintessence Int. 2010;41:639-44. |
|
|
|
25.
Stacchi C, Vercellotti T, Torelli L, Furlan F, Di Lenarda R. Preparation
Techniques: Twist Drills versus Piezosurgery. A Single-Blinded, Randomized,
Controlled Clinical Trial. Clin Implant Dent Relat Res. 2013;15:188-97. |
|
|
|
26.
Preti G, Martinasso G, Peirone B, Navone R, Manzella C, Muzio G, et al.
Cytokines and growth factors involved in the osseointegration of oral
titanium implants positioned using piezoelectric bone surgery versus a drill
technique: a pilot study in minipigs. J Periodontol. 2007;78:716-22. |
|
|
|
27.
Cano J, Campo J. Bone implant sockets made using three different procedures:
a stability study in dogs. J Clin Exp Dent. 2012;4:e217-20. |
|
|
|
28.
Yoon HG, Heo SJ, Koak JY, Kim SK, Lee SY. Effect of bone quality and implant
surgical technique on implant stability quotient (ISQ) value. J Adv
Prosthodont. 2011;3:10-5. |
|
|
|
29.
Rodrigo D, Aracil L, Martin C, Sanz M. Diagnosis of implant stability and its
impact on implant survival: a prospective case series study. Clin Oral
Implants Res. 2010;21:255-61. |
|
|