Barberá-Millán J, Larrazábal-Morón C, Enciso-Ripoll JJ, Pérez-Pevida E, Chávarri-Prado D, Gómez-Adrián MD. Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, Osseodensification: an in vitro study. Med Oral Patol Oral Cir Bucal. 2021 May 1;26 (3):e361-7.
doi:10.4317/medoral.24231
https://dx.doi.org/doi:10.4317/medoral.24231
1. Chávarri-Prado D, Brizuela-Velasco A, Diéguez-Pereira M, Pérez-Pevida E, Jiménez-Garrudo A, Viteri-Agustín I, et al. Influence of cortical bone and implant design in the primary stability of dental implants measured by two different devices of resonance frequency analysis: An in vitro study. J Clin Exp Dent. 2020;12:242-8. |
PMid:32190194 PMCid:PMC7071536 |
2. Turkyilmaz I, McGlumphy EA. Influence of bone density on implant stability parameters and implant success: a retrospective clinical study. BMC Oral Health. 2008;8:32. |
PMid:19025637 PMCid:PMC2614413 |
3. Herrero-Climent M, Santos-García R, Jaramillo-Santos R, Romero-Ruiz MM, Fernández-Palacin A, Lázaro-Calvo P, et al. Assessment of Osstell ISQ's reliability for implant stability measurement: A cross-sectional clinical study. Med Oral Patol Oral Cir Bucal. 2013;18:877-82. |
PMid:24121909 PMCid:PMC3854080 |
4. Karl M, Grobecker-Karl T. Effect of bone quality, implant design, and surgical technique on primary implant stability. Quintessence Int. 2018;49:189-98. |
PMid:29363678 |
5. Javed F, Romanos GE. The role of primary stability for successful immediate loading of dental implants. A literature review. J Dent. 2010;38:612-20. |
PMid:20546821 |
6. Çehreli M, Kökat A, Comert A, Akkocaoğlu M, Tekdemir I, Akça K. Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets. Clin Oral Implants Res. 2009;20:1163-9. |
PMid:19681964 |
7. Huwais S, Meyer E. A Novel Osseous Densification Approach in Implant Osteotomy Preparation to Increase Biomechanical Primary Stability, Bone Mineral Density, and Bone-to-Implant Contact. Int J Oral Maxillofac Implants. 2017;32:27-36. |
PMid:27741329 |
8. Baldi D, Lombardi T, Colombo J, Cervino G, Perinetti G, Di Lenarda R, Stacchi C. Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design. Biomed Res Int. 2018;2018:1-6. |
PMid:29862286 PMCid:PMC5976959 |
9. Santamaría-Arrieta G, Brizuela-Velasco A, Fernández-González FJ, Chávarri-Prado D, Chento-Valiente Y, Solaberrieta E, et al. Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis. J Clin Exp Dent. 2016;8:e307-e11. |
PMid:27398182 PMCid:PMC4930641 |
10. Brizuela-Velasco A, Álvarez-Arenas A, Gil-Mur FJ, Herrero-Climent M, Chávarri-Prado D, Chento-Valiente Y, et al. Relationship between insertion torque and resonance frequency measurements, performed by resonance frequency analysis, in micromobility of dental implants: an in vitro study. Implant Dent. 2015;24:607-11. |
PMid:26288162 |
11. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res. 1996;7:261-7. |
PMid:9151590 |
12. Sennerby L, Meredith N. Resonance frequency analysis: measuring implant stability and osseointegration. Compend Contin Educ Dent. 1998;19:493-502. |
PMid:9693511 |
13. Lekholm U. Surgical considerations and possible short comings of host sites. J Prosthet Dent. 1998;79:43-8. |
PMid:947454 |
14. Marković A, Calvo-Guirado J, Lazić Z, Gómez-Moreno G, Ćalasan D, Guardia J, et al. Evaluation of Primary Stability of Self-Tapping and Non-Self-Tapping Dental Implants. A 12-Week Clinical Study. Clin Implant Dent Relat Res. 2011;15:341-9. |
PMid:22171668 |
15. Rastelli C, Falisi G, Gatto R, Galli M, Saccone E, Severino M, Di Paolo C. Implant stability in different techniques of surgical sites preparation: an in vitro study. Oral Implantol. 2014;2:33-9. |
PMid:25694799 |
16. Sadeghi R, Reza A, Miremadi A. Comparison of Implant Stability Using Resonance Frequency Analysis: Osteotome Versus Conventional Drilling. J Dent (Tehran). 2015;12:647-54. |
PMid:27148375 |
17. Moon SH, Um HS, Lee JK, Chang BS, Lee MK. The effect of implant shape and bone preparation on primary stability. J Periodontal Implant Sci. 2010;40:239-43. |
PMid:21072221 PMCid:PMC2967812 |
18. Pérez-Pevida E, Brizuela-Velasco A, Chávarri-Prado D, Diéguez-Pereira M, Jiménez-Garrudo A, Montalbán-Vadillo O, et al. Influence of time on primary stability of dental implants placed with osteotomes due to the elastic properties of peri-implant bone. J Dent Sci. 2019;14:358-64. |
PMid:31890122 PMCid:PMC6921116 |
19. Padhye NM, Padhye AM, Bathavadekar NB. Osseodensification. A systematic review and qualitative analysis of published literature. J Oral Biol Craniofac Res. 2020;10:375-80. |
PMid:31737477 PMCid:PMC6849357 |
20. Lahens B, Neiva R, Tovar N, Alifarag AM, Jimbo R, Bonfante EA, et al. Biomechanical and histologic basis of osseodensification drilling for endosteal implant placement in low density bone. An experimental study in sheep. J Mech Behav Biomed Mater. 2016;63:56-65. |
PMid:27341291 |
21. Trisi P, Berardini M, Falco A, Vulpiani MP. New osseodensification implant site preparation method to increase bone density in low-density bone: in vivo evaluation in sheep. Implant Dent. 2016;25:24-31. |
PMid:26584202 PMCid:PMC4770273 |
22. Farré-Pagés N, Augé-Castro ML, Alaejos-Algarra F, Mareque-Bueno J, Ferrés-Padró E, Hernández-Alfaro F. Relation between bone density and primary implant stability. Med Oral Patol Oral Cir Bucal. 2011;16:62-7. |
PMid:20711163 |
23. Díaz-Castro MC, Falcao A, López-Jarana P, Falcao C, Rios-Santos JV, Fernández-Palacín A, et al. Repeatability of the resonance frequency analysis values in implants with a new technology. Med Oral Patol Oral Cir Bucal. 2019;24:e636-42. |
PMid:31422408 PMCid:PMC6764718 |
24. Pagliani L, Sennerby L, Petersson A, Verrocchi D, Volpe S, Andersson P. The relationship between frequency analysis (RFA) and lateral displacement of dental implants: an in vitro study. J Oral Rehabil. 2013;40:221-7. |
PMid:23278128 |
25. Kim DS, Lee WJ, Choi SC, Lee SS, Heo MS, Huh KH, et al. Comparison of dental implant stabilities by impact response and resonance frequencies using artificial bone. Med Eng Phys. 2014;36:715-20. |
PMid:24378382 |
26. Ahn SJ, Leesungbok R, Lee SW, Heo YK, Kang KL. Differences in implant stability associated with various methods of preparation of the implant bed: An in vitro study. J Prosthet Dent. 2012;107:366-72. |
PMid:22633592 |
27. Wang TM, Lee MS, Wang JS, Lin LD. The effect of implant design and bone quality on insertion torque, resonance frequency analysis, and insertion energy during implant placement in low or low-to medium-density bone. Int J Prosthodont. 2015;28:40-47. |
PMid:25588172 |
28. Tabassum A, Meijer GJ, Wolke JGC, Jansen JA. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study. Clin Oral Implants Res. 2010;21:213-20. |
PMid:20070754 |
29. Sanz-Sánchez I, Sanz-Martín I, Figuero E, Sanz M. Clinical efficacy of immediate implant loading protocols compared to conventional loading depending on the type of the restoration: a systematic review. Clin Oral Implants Res. 2015;26:964-82. |
PMid:24917174 |
30. Xing Y, Khandelwal N, Petrov S, Drew HJ, Mupparapu M. Resonance frequency analysis (RFA) and insertional torque (IT) stability comparisons of implants placed using osteotomes versus drilling techniques: a preliminary case study. Quintessence Int. 2015;46:789-98. |
PMid:26159207 |
31. Lee DH, Ku Y, Rhyu IC, Hong JU, Lee CW, Heo MS, Huh KH. A clinical study of alveolar bone quality using the fractal dimension and the implant stability quotient. J Periodontal Implant Sci. 2010;40:19-24. |
PMid:20498755 PMCid:PMC2872807 |